Error Analysis on KIC Converted from JIC for Ti80 Alloy
The error of KIC converted from JIC was analyzed.The main reason to the errors was that the specimen didn't meet the requirements of small scale yielding.An correction idea of crack size was applied and therefore the error was reduced from 12% to 5%.